John Hawkins - Authentication Issue in Webspeed (WHI-2902)

Module

Utilities

Component

Generic

Date

 

Module

Utilities - Generic

Menu Selection

Pulse Webspeed login - no menu selection

Release Note Details

An issue was discovered in the Pulse Webspeed login process where only the first three characters of the entered requisitioner code were used for validating credentials.

As an example, say the requisitioner PUL existed in the system. A user could mistakenly enter the requisitioner code "PULSE", and if they provided the PIN/Password associated with requisitioner PUL, that person would be logged in as PUL.

The following packages are required to resolve this issue:

2018.00 Release

CommitPackage
28153SUP-dp
28152UTL-gen

2019.00 Release

CommitPackage
28156SUP-dp
28155UTL-gen

Setup Details

None



Test Plan

Test Description

Demonstrate that credentials to Pulse Webspeed are validated correctly.

Test Plan Details

#Feature /Test ScenarioExpected ResultsResultsNotes
1Attempt to log in to Webspeed using a requisitioner code > 3 characters, where the first 3 characters match a valid requisitioner codeLogin failed(tick)


2Log in to Webspeed using a valid requisitioner code and PIN/PasswordLogin successful(tick)


  1. Attempt to log in to Webspeed using a requisitioner code > 3 characters, where the first 3 characters match a valid requisitioner code





  2. Log in to Webspeed using a valid requisitioner code and PIN/Password